66KV Polymer Line Post Insulator

66KV Polymer Line Post Insulator
Product Detailed
66KV Polymer Line Post Insulator 1.Model:FZSW 2.Rated voltage:110kv, 10kv, 35kv, 66kv

66KV Polymer Line Post  Insulator 

 

Brief introduction of 66KV Polymer Line Post  Insulator 

Brand name

Shentai

Product rage

FZSW-110KV,  FZSW-10KV, FZSW-35KV, FZSW-66KV

Rated voltage

110kv, 10KV, 35kv 66kv

66KV Polymer Line Post  Insulator 

Product structure:

This product series is made of glass fiber epoxy resin lead pull rod, silicone rubber umbrella skirt and hardware fittings. The rubber umbrella skirt adopts whole injection molding process to solve the problem of interface electric puncture. Binding and pressure welding process are used to connect glass fiber epoxy resin lead pull rod and armour clamp.  The product has the characteristics of nice appearance, small volume and light duty. Galvanized hardware fittings can prevent rust, and are used interchangeably with porcelain insulator. The reliable structure of binding and pressure welding can give play to mechanical strength without damaging the core rod.

66KV Polymer Line Post  Insulator 

Product 

Properties

superior electric property, strong 

mechanical strength

Excellent pollution resistant, 

strong anti-pollution flashover ability

Small volume, light duty(only 1/6-1/19 of the 

same voltage porcelain insulator ), lightweight structure, 

easy to transport and insulate.

silicone rubber umbrella skirt has the characteristic 

of excellent hydrophobicity and the whole structure

 protects  the internal insulation from moisture. 

There is no need to test the prevention performance 

and clean, which reduce the daily work load.

Excellent tightness and low temperature resistance

Working environment;-40°C-+50°C

 Strong impact resistance and antiknock 

 characteristic, excellent brittle resistance and creep resistance.

Drawing of   66KV Polymer Line Post  Insulator 

FZSW-110KV

FZSW-10KV

FZSW-35KV

FZSW-66KV

Parameters of   66KV Polymer Line Post  Insulator 

Item

Model

Rated voltage 

KV

Rated mechanical bending failure load

KN

Structure height 

 H

(mm)

insulation distance

  h

(mm)

Minimum

nominal creepage distance

mm

Lightning impulse withstand voltage KV(peak)

Power frequency  withstand voltage

effective value 

KV

Bar pillar composite insulator

FZSW-126/8

110

8

1200

1080

2750

500

230

FZSW-10KV

Item

Model

Rated voltage 

KV

Rated mechanical bending failure load

KN

Structure height 

 H

(mm)

insulation distance

  h

(mm)

Minimum

nominal creepage distance

mm

Lightning impulse withstand voltage KV(peak)

Power frequency  withstand voltage

effective value 

KV

Bar pillar composite insulator

FZSW-10/4

10

4

250

180

380

85

46

FZSW-35KV

Item

Model

Rated voltage 

KV

Rated mechanical bending failure load

KN

Structure height 

 H

(mm)

insulation distance

  h

(mm)

Minimum

nominal creepage distance

mm

Lightning impulse withstand voltage KV(peak)

Power frequency  withstand voltage

effective value 

KV

Bar pillar composite insulator

FZSW-35/4

35

4

445

400

1320

230

95

FZSW-66KV

Item

Model

Rated voltage 

KV

Rated mechanical bending failure load

KN

Structure height 

 H

(mm)

insulation distance

  h

(mm)

Minimum

nominal creepage distance

mm

Lightning impulse withstand voltage KV(peak)

Power frequency  withstand voltage

effective value 

KV

Bar pillar composite insulator

FZSW-72.5/10

66

10

770

680

1450

350

150

Photos of  66KV Polymer Line Post  Insulator 