- Contact Person : Ms. Zhu Angela
- Company Name : Henan Shenyu Power Equipment Co., Ltd.
- Tel : 86-373-5850238
- Fax : 86-373-5850238
- Address : Henan,Xinxiang,No.103 Jinsui Road
- Country/Region : China
- Zip : 453000
66KV 69 KV Polymeric Linepost insulator
66KV 69 KV Polymeric Linepost insulator
Brief introduction of 66KV 69 KV Polymeric Linepost insulator
Brand name | Shentai |
Product rage | FZSW-110KV, FZSW-10KV, FZSW-35KV, FZSW-66KV |
Rated voltage | 110kv, 10KV, 35kv 66kv |
66KV 69 KV Polymeric Linepost insulator
Product structure:
This product series is made of glass fiber epoxy resin lead pull rod, silicone rubber umbrella skirt and hardware fittings. The rubber umbrella skirt adopts whole injection molding process to solve the problem of interface electric puncture. Binding and pressure welding process are used to connect glass fiber epoxy resin lead pull rod and armour clamp. The product has the characteristics of nice appearance, small volume and light duty. Galvanized hardware fittings can prevent rust, and are used interchangeably with porcelain insulator. The reliable structure of binding and pressure welding can give play to mechanical strength without damaging the core rod.
66KV 69 KV Polymeric Linepost insulator
Product Properties | superior electric property, strong mechanical strength |
Excellent pollution resistant, strong anti-pollution flashover ability | |
Small volume, light duty(only 1/6-1/19 of the same voltage porcelain insulator ), lightweight structure, easy to transport and insulate. | |
silicone rubber umbrella skirt has the characteristic of excellent hydrophobicity and the whole structure protects the internal insulation from moisture. There is no need to test the prevention performance and clean, which reduce the daily work load. | |
Excellent tightness and low temperature resistance Working environment;-40°C-+50°C | |
Strong impact resistance and antiknock characteristic, excellent brittle resistance and creep resistance. |
Drawing of 66KV 69 KV Polymeric Linepost insulator
FZSW-110KV
FZSW-10KV
FZSW-35KV
FZSW-66KV
Parameters of 66KV 69 KV Polymeric Linepost insulator
Item | Model | Rated voltage KV | Rated mechanical bending failure load KN | Structure height H (mm) | insulation distance h (mm) | Minimum nominal creepage distance mm | Lightning impulse withstand voltage KV(peak) | Power frequency withstand voltage effective value KV |
Bar pillar composite insulator | FZSW-126/8 | 110 | 8 | 1200 | 1080 | 2750 | 500 | 230 |
FZSW-10KV
Item | Model | Rated voltage KV | Rated mechanical bending failure load KN | Structure height H (mm) | insulation distance h (mm) | Minimum nominal creepage distance mm | Lightning impulse withstand voltage KV(peak) | Power frequency withstand voltage effective value KV |
Bar pillar composite insulator | FZSW-10/4 | 10 | 4 | 250 | 180 | 380 | 85 | 46 |
FZSW-35KV
Item | Model | Rated voltage KV | Rated mechanical bending failure load KN | Structure height H (mm) | insulation distance h (mm) | Minimum nominal creepage distance mm | Lightning impulse withstand voltage KV(peak) | Power frequency withstand voltage effective value KV |
Bar pillar composite insulator | FZSW-35/4 | 35 | 4 | 445 | 400 | 1320 | 230 | 95 |
FZSW-66KV
Item | Model | Rated voltage KV | Rated mechanical bending failure load KN | Structure height H (mm) | insulation distance h (mm) | Minimum nominal creepage distance mm | Lightning impulse withstand voltage KV(peak) | Power frequency withstand voltage effective value KV |
Bar pillar composite insulator | FZSW-72.5/10 | 66 | 10 | 770 | 680 | 1450 | 350 | 150 |
Photos of 66KV 69 KV Polymeric Linepost insulator
Please kindly inform the following information when you email us.
1.Model
2.Rated voltage
66KV 69 KV Polymeric Linepost insulator